Advanced Multi-Spec Fuel/Water Separator Test Stand

The Model 12230 performs fully automated and unattended testing of fuel/water separators used on diesel engines per IS0 16332, SAE J1488 and SAE J1839. The system features a “patent pending” automatic sampling, sonication and titrating system with high accuracy and repeatability.

MORE PHOTOS
Advanced Multi-Spec Fuel/Water Separator Test Stand Advanced Multi-Spec Fuel/Water Separator Test Stand Advanced Multi-Spec Fuel/Water Separator Test Stand Advanced Multi-Spec Fuel/Water Separator Test Stand

Fuel Circuit:
Flow Range 1-25 Lpm
Flow Accuracy (dual flow meters) 0.1% of reading
Temperature Control ±2ºC
Static Pressure Control 0-140 kPa ±14 kPa (0-20 psig ±2 psig)
Differential Pressure Control 1-260 hPa ±1 hPa (0-4 psi ±0.15 psi)
Fuel Tank Capacity 325 L
Fuel Tank Outlet Configuration Both SAE & ISO
Waste Tank Capacity 15 L
Tank and Tubing Material Stainless Steel
Fuller’s Earth Conditioning Circuit Included
Optional Fuel Preparation Cart 75 L capacity with Fuller’s Earth treatment
   
Water Circuit:
Deionized Water Supply Rate 0.9 Lpm
Metering Pump Injection Precise Automatic Ratio Control
Injection Rate 1.0-576 mLpm
Clean-up Filter Rating 30 ppm @ 25 Lpm w/ automatic drain
Optional Water Collection Cart 75 L capacity
   
Analysis Circuit:  
Automatic Sampling and Titration Provides Near Real-Time Results (Patent Pending)
Repeatability exceeds ISO requirement of 2%±0.1%
K-T Titration Water Content Measurement 0.3% reproducibility
   
User Interface, Controls and Data Acquisition:
CPU Dell OptiPlex w/ Intel Core™ processor or equal
Operating System Microsoft Windows 7
User Interface 22" LCD monitor, keyboard & mouse
I/O Hardware Platform National Instruments CompactRIO
Application Software Custom NI LabView executable w/ graphical displays, performs ISO 16332, SAE J1488 & SAE J1839 procedures
Data Output Tabular and graphical test reports, .xlsx files
   
Utility Requirements & Environmental:
Electrical 480 Vac/3Ph/ 60Hz/25A (International voltages available)
Tap Water 1.0 Lpm @ 400-700 kPa (.26 gpm @60-100 psig)
Cooling Water Customized to customer’s cooling water source
Compressed Air 0.14 m3/min @ 550 kPa (5 cfm @ 80 psig), dry & oil free
Ventilation 150mm (6") connection
Ambient Operating Temperature 10-40 ºC (50-104ºF)
Noise Output 82 dBA

 

Download the Testand Fuel Water Separator Test Stand pdf.


Fatal error: Uncaught yii\web\HeadersAlreadySentException: Headers already sent in /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/web/Response.php on line 434. in /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/web/Response.php:369 Stack trace: #0 /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/web/Response.php(342): yii\web\Response->sendHeaders() #1 /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/web/ErrorHandler.php(136): yii\web\Response->send() #2 /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/craftcms/cms/src/web/ErrorHandler.php(199): yii\web\ErrorHandler->renderException() #3 /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/base/ErrorHandler.php(323): craft\web\ErrorHandler->renderException() #4 [internal function]: yii\base\ErrorHandler->handleFatalError() #5 {main} thrown in /home/217483.cloudwaysapps.com/tvzkbmqqum/public_html/craft/vendor/yiisoft/yii2/web/Response.php on line 369